Equipment
The Equotip consists on the Impact device and the control/logging box. Seen below the impact device consists of a 3mm dia. Spherical shaped tungsten carbide test tip which is spring mounted in an impact body. The test tip impacts on the test surface under spring force from which it rebounds.
The velocity that the impact body is impelled and rebounds with is measured by the passing of a permanent magnet through a coil of wire. This induces a voltage proportional to the devices velocity.
The LEEB hardness value is the quotient of the impelled velocity over the rebound velocity multiplied by 1000. Harder materials will rebound the impact device giving higher LEEB hardness values.
Equotip 3 vs Equotip 2
- Automatic correction for the orientation of the probe. A larger screen with backlight
- Choice to use internally rechargeable batteries or standard “C” Batteries
- Connection to PC using USB or Ethernet.
- New and Improved Equolink 3 software has also been introduced.
Ring Supports
Accurate testing using the Equotip 2 relies on the test specimen being immobilized. This can be achieved using a simple test jig firmly connected to a heavy vibration resistant base. Furthermore the Support Ring (part 6) is designed to give a firm connection between the Impact Device and the core. The standard support ring I ideal for cores with radius greater than 60mm and flat surfaces. The Z14.5 to 30 support ring allows testing of cores between 29 and 60mm dia.
Impact Device Type S
The S type impact device uses highly durable material in the test tip in the impact body of the standard D type Impact Device. This improved durability is ideal for core logging because it prolongs the usage of the Impact Device between servicing.