Linked In YouTube Google Plus
E31.2 E32.2

MEMS IN-PLACE Tilt Meter

TlitmeterMEMS In-Place Tilt Meters are designed to measure uniaxial or biaxial tilt, which is measured from the plane(s) perpendicular from the base unit.

It is designed to be installed permanently in either the vertical or horizontal position by either bonding or bolting directly to a structure or mounting plate. Data is read via a cable with either a portable readout or connected into a data logger.

The tilt sensor is mounted within a rugged, heavy duty waterproof cast metal enclosure suitable for the harsh environments found within the construction and building industries.
Available as an analogue or digital (RS-485) version, it offers a range of output signals including voltage, milli-amps and digital bus. The digital bus version allows several tilt meters to be daisy-chained together on a single cable over 1000 metres long.

Each unit is individually calibrated to provide the ultimate in system accuracy and repeatability and can be used in conjunction with most data-loggers.

Features

  • Ultimate accuracy and repeatability
  • Uniaxial or biaxial sensors option
  • EMC-CE & LUL compliant
  • LSHF cable option
  • Horizontal or vertical mounting
  • Easy to install
  • Digital bus available (RS-485)
  • Analogue output
  • IP66 waterproof enclosure
  • Durable powder coating
  • Cost effective

Applications

For monitoring tilt in:

  • Retaining walls
  • Diaphragm walls
  • Concrete dams
  • Party walls
  • Structures
  • Bridge piers
  • Tunnels
  • Compensation grouting
  • Slopes
  • Piles

Specifications

 ITEM  IPTM-1-420  IPTM-2-420  IPTM-1-010  IPTM-2-010  IPTM-1-485  IPTM-2-485
 Range  ±15°  ±15°  ±15°  ±15°  ±15°  ±15°
 Axis  Uniaxial  Biaxial  Uniaxial  Biaxial  Uniaxial  Biaxial
 Output  4-20mA  4-20mA  +/-5 Volts  +/-5 Volts  RS485  RS485
 Resolution  5 arc sec  5 arc sec  5 arc sec  5 arc sec  5 arc sec  5 arc sec
 Non linearity  ±0.05% FS  ±0.05% FS  ±0.05% FS  ±0.05% FS  ±0.0125% FS  ±0.0125% FS
 Repeatability  ±0.0125% FS  ±0.0125% FS  ±0.0125% FS  ±0.0125% FS  ±0.0125% FS  ±0.0125% FS
 Sensor  MEMS  MEMS  MEMS  MEMS  MEMS  MEMS
 Excitation  8-15 V DC  8-15 V DC  8-15 V DC  8-15 V DC  8-15 V DC  8-15 V DC
 Operating  Temp  -40 to +85°C  -40 to +85°C  -40 to +85°C  -40 to +85°C  -40 to +85°C  -40 to +85°C
 Dimensions  125x80x60mm  125x80x60mm  125x80x60mm  125x80x60mm  125x80x60mm  125x80x60mm


Accessories

  • Horizontal mounting plate
  • Vertical mounting bracket
  • MEMS analogue readout
  • Ultra-rugged field PC
  • Digital interface RS-485

Additional Information

MEMS Tiltmeter Brochure

VIC:

Melbourne

This email address is being protected from spambots. You need JavaScript enabled to view it.

t (03) 9938 3830

f (03) 9938 3899

m 0428 315 502

NSW:

Sydney

e This email address is being protected from spambots. You need JavaScript enabled to view it.

t (02) 9986 1857

m 0418 381 709

QLD:

Brisbane

e This email address is being protected from spambots. You need JavaScript enabled to view it.

t (07) 3040 6166

m 0419 477 715

 

WA:

Perth (Head Office)

e This email address is being protected from spambots. You need JavaScript enabled to view it.

t (08) 9322 4020

m 0408 034 668

Linked In YouTube Google Plus